LAB 02 / INFRASTRUCTURE
Engineering, in perspective.
Three structures. Multiple mounting levels. Explore utilization immediately with teaching assumptions, then compare your project limits.
Guyed mast
Rings and equipment colors compare equipment mass at each level with its limit. Red marks a level overload. Global wind and mass limits are assessed separately below.
SCENARIO SETTINGS
Make it yours.
Changes update the model and the applied loads.
EQUIPMENT SCHEDULE
Every level. Every added load.
Create mounting levels, add equipment and edit its actual mass and effective wind area. Loads are calculated at each mounting height.
Equipment presets are editable examples, not manufacturer specifications. Effective area includes the force coefficient for the selected wind direction. Up to 60 units and eight levels per experiment.
LOAD / CAPACITY ASSUMPTION
See the remaining headroom.
Start exploring immediately with assumed teaching limits. Add equipment or change its height to see utilization and remaining headroom. Use project limits when you have engineering records.
Inspect or edit the capacity assumptions
These are independent demand/reference ratios. Their maximum is a screening indicator, not a combined code utilization or structural approval. Wind and weight limits must use a compatible design basis. For guyed masts, the global external moment is not the mast-base internal moment.
Click a part in the 3D view to understand its role. Geometry is illustrative; only the stated inputs are used in the load calculation.
A clearer view of the forces
LIVE LOAD BREAKDOWN| Component | Wind force · kN | Moment · kN·m |
|---|
Method & referencesEU / Sweden
Implemented in this lab
For each equipment group, effective wind area = quantity × supplied area per unit, mass = quantity × mass per unit, force F_i = q_p × c_s c_d × A_eff,i, and global external moment M_i = F_i × mounting height. All mounting-level actions are summed with a structure wind area distributed uniformly over its height. Equipment weight uses g = 9.80665 m/s². Effective area includes the force coefficient for the selected direction. Project q_p and structural factor must be supplied on an appropriate Eurocode/Swedish project basis; defaults are illustrative. Optional global wind-moment, wind-force, total equipment-mass and mounting-level mass limits produce independent demand/entered-limit ratios. The highest supplied ratio is a screening indicator; unprovided limits remain unassessed. No maximum structural capacity is inferred from type, height or 3D geometry. The optional worked example explicitly supplies illustrative limits, not a structure rating. The interface starts in teaching-assumption mode with fixed illustrative envelopes for the mast, lattice tower and monopole. Immediate utilization and remaining headroom are the highest independent global or level-mass comparison. Changing equipment or wind changes demand without changing those limits. Assumptions can be edited, restored or replaced through project-limit mode, which clears the assumed global and level limits. An export records the capacity basis. Teaching defaults are not inferred structural resistance or manufacturer ratings. Each 3D level ring and label compares its equipment mass with that level’s limit: below 80% green, 80–100% amber, above 100% red, and missing limits grey. Equipment on an overloaded level is tinted red; a global wind overload does not mark all local levels as overloaded. A separate base ring and scene warning indicate global exceedance. Quick panel controls add 30 kg and 0.8 m² at the selected level.
Model limits
This is an applied-action and reference-limit screening model, not a code resistance verification. It does not derive site wind pressure, load combinations or partial factors, force/dynamic coefficients, member buckling, axial/bending interaction, torsion, eccentric gravity actions, fatigue, ice, deflection, guy tensions or pretension, mount/connection resistance, foundation capacity or geotechnical resistance. Independent reference ratios cannot establish combined structural utilization or approval. The global external moment of a guyed mast is not the internal mast-base moment. Reference limits must correspond to the same structure, wind direction and loading/design basis. Equipment examples and 3D shapes are illustrative. Direct-speed mode remains q = 0.5 × 1.225 × V², a simplified physics example.
Swedish deployment context
Use the applicable EN 1990 basis, EN 1991-1-4 wind actions and EN 1993 tower/mast steel provisions with Swedish national choices, and establish which BFS 2024:6 requirements apply. EKS was repealed on 1 July 2026; historic projects may have a transitional basis. SIS has published a second-generation 2026 tower standard; publication alone does not establish national applicability. Record the project’s edition and national annex.
- Boverket · Eurocodes and Swedish national annexes ↗
- Boverket · Wind actions / BFS 2024:6 ↗
- BFS 2024:6 · Official regulation ↗
- Boverket · EKS transition and repeal ↗
- SIS · SS-EN 1993-3:2026, towers, masts and chimneys ↗
Reference review: 15 November 2026 · Educational scope, no certification or regulatory approval.
BUILD WITH ASP
Your challenge. Your environment.
Need a version for your organisation or country? Talk to ASP about adapting a lab or building a telecom solution for your environment.